AXISx.FAULT2018.ACTION

Description

This parameter determines the action the servo drive should take when F6004 occurs.

Parameter Value Drive Action
0 Disable Axis
1 Ignore (fault will not be reported)
2 Controlled Stop
3 Dynamic Brake
4 Generate Warning (See W6030)

Versions

Action Version Notes
Implemented 02-14-04-001

General Information

Type

Read/Write

Units

N/A

Range

0 to 4

Default Value

0

Data Type

Integer

Stored in Non-Volatile Memory

Yes

Variants Supported

All variants are supported.

Industrial Ethernet Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.FAULT2018.ACTION

501ch

04h

Unsigned8

-

-

Read/Write

No

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

7203

1

7203 (0x1c23)

AXIS1.FAULT2018.ACTION

Unsigned8

Read/Write

Yes

PROFINET

Parameter

PNU

Data Type

Access

Units

AXIS1.FAULT2018.ACTION

7203

Unsigned8

Read/Write

-